title: "Regulations applying to medical devices"
url: https://normiq.app/en/regulations
language: en
updated: 2026-09-03
---

# Regulations applying to medical devices

Each entry states what the text requires, which classes it applies to, since when, and links to its official source. Statements are verified against the primary text.

## Founding texts

The EU regulations and their structuring articles: what binds you, and directly.

- [MDR 2017/745 Regulation (EU) 2017/745 on medical devices](https://normiq.app/en/regulations/mdr-2017-745)
- [MDR Art. 10 General obligations of manufacturers](https://normiq.app/en/regulations/mdr-art-10)
- [MDR Art. 52 Conformity assessment procedures](https://normiq.app/en/regulations/mdr-art-52)
- [MDR Art. 61 Clinical evaluation and clinical investigations](https://normiq.app/en/regulations/mdr-art-61)
- [MDR Art. 120 Transitional provisions](https://normiq.app/en/regulations/mdr-art-120)
- [MDR Art. 29 et 31 Registration of devices and economic operators in EUDAMED](https://normiq.app/en/regulations/mdr-art-29-et-31)
- [MDR Art. 27 Unique Device Identification system (UDI)](https://normiq.app/en/regulations/mdr-art-27)
- [MDR Annexe I General safety and performance requirements](https://normiq.app/en/regulations/mdr-annexe-i)
- [MDR Annexe VIII Classification rules](https://normiq.app/en/regulations/mdr-annexe-viii)
- [IVDR 2017/746 Regulation (EU) 2017/746 on in vitro diagnostic medical devices](https://normiq.app/en/regulations/ivdr-2017-746)
- [IVDR Art. 47 Classification of in vitro diagnostic devices](https://normiq.app/en/regulations/ivdr-art-47)
- [IVDR Art. 56 Performance evaluation](https://normiq.app/en/regulations/ivdr-art-56)
- [IVDR Art. 57 à 77 Performance studies](https://normiq.app/en/regulations/ivdr-art-57-a-77)
- [MDR Art. 15 Person responsible for regulatory compliance](https://normiq.app/en/regulations/mdr-art-15)

## Harmonised standards

The standards that grant a presumption of conformity. Following them is not mandatory; departing from them requires a written justification.

- [ISO 13485:2016 Medical devices — Quality management systems](https://normiq.app/en/regulations/iso-13485-2016)
- [ISO 14971:2019 Application of risk management to medical devices](https://normiq.app/en/regulations/iso-14971-2019)
- [IEC 62304:2006 Medical device software — Software life cycle processes](https://normiq.app/en/regulations/iec-62304-2006)
- [IEC 60601-1:2020 Medical electrical equipment — Basic safety and essential performance](https://normiq.app/en/regulations/iec-60601-1-2020)
- [ISO 10993 (série) Biological evaluation of medical devices](https://normiq.app/en/regulations/iso-10993-serie)
- [ISO 14155:2020 Clinical investigation of medical devices for human subjects](https://normiq.app/en/regulations/iso-14155-2020)
- [IEC 62366-1:2015 Medical devices — Application of usability engineering](https://normiq.app/en/regulations/iec-62366-1-2015)
- [ISO 15223-1:2021 Symbols to be used with information supplied by the manufacturer](https://normiq.app/en/regulations/iso-15223-1-2021)
- [ISO 11135:2014 Sterilization of health care products — Ethylene oxide](https://normiq.app/en/regulations/iso-11135-2014)
- [ISO 11737-1:2018 Sterilization of health care products — Microbiological methods](https://normiq.app/en/regulations/iso-11737-1-2018)
- [ISO 13408-1:2023 Aseptic processing of health care products](https://normiq.app/en/regulations/iso-13408-1-2023)
- [ISO 80369 (série) Small-bore connectors for liquids and gases](https://normiq.app/en/regulations/iso-80369-serie)
- [IEC 62366-2:2016 Application of usability engineering — Part 2](https://normiq.app/en/regulations/iec-62366-2-2016)

## MDCG guidance

The coordination group’s guidance. Not binding, but what notified bodies apply.

- [MDCG 2021-24 Guidance on classification of medical devices](https://normiq.app/en/regulations/mdcg-2021-24)
- [MDCG 2020-3 Guidance on significant changes regarding the transitional provision](https://normiq.app/en/regulations/mdcg-2020-3)
- [MDCG 2020-13 Clinical evaluation assessment report template](https://normiq.app/en/regulations/mdcg-2020-13)
- [MDCG 2019-11 Guidance on qualification and classification of software](https://normiq.app/en/regulations/mdcg-2019-11)

## Post-market

What begins once the device is on the market: surveillance, periodic reports, vigilance.

- [MDR Art. 83 Post-market surveillance system](https://normiq.app/en/regulations/mdr-art-83)
- [MDR Art. 86 Periodic safety update report (PSUR)](https://normiq.app/en/regulations/mdr-art-86)
- [FR-MATERIOVIGILANCE Materiovigilance (France)](https://normiq.app/en/regulations/fr-materiovigilance)
- [CH-VIGILANCE Swissmedic vigilance](https://normiq.app/en/regulations/ch-vigilance)

## National requirements

What each country adds to the European baseline: registration, language, contact points.

- [FR-ANSM-NOTIF ANSM notification (France)](https://normiq.app/en/regulations/fr-ansm-notif)
- [FR-LANGUE French language requirement (France)](https://normiq.app/en/regulations/fr-langue)
- [DE-BFARM-REG BfArM registration (Germany)](https://normiq.app/en/regulations/de-bfarm-reg)
- [DE-MPDG Medizinprodukterecht-Durchführungsgesetz (Germany)](https://normiq.app/en/regulations/de-mpdg)
- [IT-MIN-SALUTE Ministry of Health registration (Italy)](https://normiq.app/en/regulations/it-min-salute)
- [IT-NSIS NSIS repository (Italy)](https://normiq.app/en/regulations/it-nsis)
- [ES-AEMPS-REG AEMPS registration (Spain)](https://normiq.app/en/regulations/es-aemps-reg)
- [ES-LANGUE Spanish language requirement (Spain)](https://normiq.app/en/regulations/es-langue)
- [CH-SWISSMEDIC-REG Registration of the economic operator with Swissmedic](https://normiq.app/en/regulations/ch-swissmedic-reg)
- [CH-MANDATAIRE Swiss authorised representative required](https://normiq.app/en/regulations/ch-mandataire)